| 20,000+ Fresh Resumes Monthly | |
|
|
| | Click here or scroll down to respond to this candidate RESUMECandidate's Name
E-mail: EMAIL AVAILABLEMobile No.: +Street Address -10-3148-2135 (South Korea)|Company |Duration and Role |Work summary ||Daelim |Feb-2012 to Till |Engineering coordination with IPCS Vendor. ||Industrial |Date |Detail Engineering for SADARA - TDI Plant ||Co., Ltd. |Process Automation|Project ||Seoul, South |Engineer |Co-ordination with Client & Vendor, ||Korea. | | ||WestingHouse |Apr-2011 to |Logics Implementation, Functional allocation, ||Engineering |Feb-2012 |System Architecture, Functional Requirement ||Centre- |Team Lead |Capturing. ||Infotech | | ||Enterprises | | ||India Ltd., | | ||Samsung |Apr-2010 to |Vendor/ Licensor / Client Coordination at Vendor||Engineering |Apr-2011 |facility, ||India Ltd., |Control System |FAT, Dual Feed Ethylene Cracker Logics ||Noida |Engineer |Implementation, Complex Loop Narratives, Cracker|| | |Operating Manuals. ||Honeywell |July-2006 to |Functional Design Specification for DCS, ESD and||Automation |Apr-2010 |F&G. ||India Pvt. |Engineer |Detailed Hardware Engineering for DCS, ESD and ||Ltd., Pune | |F&G Systems. || | |FAT (Factory Acceptance Test ) || | |SAT (Site Acceptance Test ) || | |Erection & commissioning of Systems. |Training / Certifications: . TUV Certified as Functional Safety Engineer. TUV ID No. 2820 / 10 . Honeywell Experion PKS SCADA & Controller Implementation . Honeywell DCS -- TPS (HPM) and C-200 controller . Honeywell Fail Safe Controller (FSC) and Safety Manager (SM) Controller . Six Sigma (Green Belt) Certified at Honeywell. . Safety training for offshore.Key Skills: . Kick-off Meeting & Scope of Work, Schedule . DCS and Safety System(ESD & FGS) Hardware and Software Functional Design Specification and Detail Design . Power and Heat Load calculation for Control system . System, Marshalling & Power Cabinets GA drawing . IO Assignment and Marshalling Cabling Database . Third-party system interface, communication configuration & testing (Serial - RS232/RS485, Modbus TCP/IP) . EPC Inter-disciplinary Document review . Licensor / Client Meeting and design clarification . P&ID review & Markup Updates . Management of Design input Change and thorough Documentation . Prepare Cause & Effect (C&E), Control Narrative. . Develop & Implement Logic as per P&ID, C&E, Control Narrative in Control System. . Plan Pre-FAT and FAT as per project Schedule . Cold and Hot Loop Check and Pre-Commissioning & Commissioning Activity . Site Installation, Erection and SAT (Site Acceptance Test)Present Employer:Daelim Industrial Co., Lt., Seoul -South Korea 1. SADARA Isocyanates Plant- Al Jubail, KSA (Presently Working on Engineering) Licensor: Dow Chemicals Company. System: ABB 800xA DCS Control and Safety System. . Co-ordination with Daelim Process and DOW for design documents . Detail Engineering with good understanding of TDI plant . Define and Implement Control Strategy & Interlocks . Intense testing of Dynamic Model (RSI-France) and Control logic for CV-OTS -- TDI Plant. . SIS logic implementation and testing . Vendor prints Review & coordination with IPCS Vendor. 2. SAHARA and Ma'Aden Petrochemical Company (SAMAPCO) - Al Jubail, KSA System: Yokogawa Centum VP DCS, ProSafe RS ESD/ FGS. . Co-ordination with Daelim Process Team, Logic Preparation and Pre-SAT . Co-ordination with Vendors . Conducting Site Acceptance Test (SAT) for Yokogawa DCS / SIS / FGS and successfully completed.Previous Employers:Westing Engineering Centre, Infotech Enterprises India Ltd., Hyderabad 1. Sanmen Nuclear Power Station, Sanmen, China System: Ovation DCS - Emerson . Functional Requirement Capturing. . Logic Implementation in OvationSamsung Engineering India Ltd. (SEIL) , Noida 1. ONGC Petro additions Ltd. (OPaL Ethylene Project), Bharuch (USD 1.4 Billion) System: Honeywell C300 DCS, Safety Manager (SM) ESD/ FGS. . Primary Link between System Vendor & Samsung . Responsible for all Coordination activities like o BPCS / SIS / FGS Engineering o BPCS / SIS / FGS Integrated Testing o I/O Assignment o Troubleshooting for Technical queries . Responsible for Hardwire design issues for o System Cabinet o Marshalling Cabinet o Hardwired Console Layout o Power Supplies o IO Database preparation . Power and Heat Load Calculation . Conducted FAT (Factory Acceptance Test) for Ethylene Cracker Unit . Lead a team of 3 engineers as area lead for Cracker for detail Control System engineering. . Control Room Layout . JB Grouping . Logic development as Licensor P&ID, Control Narratives and Interlock(C&E) for Dual Feed - Ethylene Crackers Units.Honeywell Automation India Ltd. (HAIL), Pune 1. Sulphur Recovery Unit-3 - HPCL, Vizag. System: - Honeywell Fail Safe Controller (FSC) withHoneywell High Performance Manager (HPM). . Logic Implementation in FSC Controller. . FSC interface with Honeywell HPM(TPS) system. . Conducting FAT of the total integrated system: Complete Hardware and software & Loop checking.2. LPG Mounded Bullet - IOCL, Baroda System: - DCS C-200 with Plantscape Scada withFSC safety system (ESD system) On MODBUS. . Third party communication with Enraf and E&H CIU on MODBUS. . Logic Checking along with Graphics Linking and Hot loop checking and commissioning of the plant. 3. Gas Receiving Terminal - IPCL, Nagothane System: - Honeywell High Performance Manager (HPM). . Involved in FAT: Hardware check, software Logic check, IO Loop check. . MODBUS communication with RTU: installed a BOW networks protocol converter, that Converts Nokia Connitel 2025 protocol to MODBUS protocol. . Panel Installation, Powering Up system and Pre-commissioning. 4. Green Fuel Emission Control - HPCL, Chembur (Mumbai) System: - EPKS (C-200 release 301) on FTEB and FSC safety system . DCS C-200 and FSC system powering up. . On site Logic Checking along with Graphics Linking & Loop Checking. . Pre-commissioning of the plant. 5. ONGC - SH Complex OFFSHORE (ONGC-South field). System: - EPKS (C-200 release 210) on FTEB and SM& FSC safety system (ESD and Fire & Gas system). . Logic checking and graphics linking with logic. . HART Maintenance system: configuration of transmitters (Cornerstone software). . Commissioning of DCS, ESD & F&G system. 6. Successfully completed SAT at MRPL - LPG Mounded Bullet Storage Facilities 7. Hindustan Oil Exploration Corporation Ltd. - Cuddalore . Logic Understanding and Implementation in Honeywell Safety Manager System as ESD system. 8. LPG & Propylene Mounded Bullet Storage Facilities Project - HPCL, Vizag. System: - Safety Manager (Safety Builder release R131.5) . Preparation of Functional Design Specification for ESD System . Detail Engineering: BOM preparation, System Hardware Designing . IO Assignment, Wiring Database Preparation . Logic understanding & development . Panel Installation, Powering Up system and Pre-commissioning . Planning, Erection & installation of field instruments & F&G detectors and accessories (Cable tray routing, Glanding) . Planning, Erection & installation of Junction Boxes and accessories (Cable tray routing, Glanding) 9. New DCS for BPCL KRL Unit Project. . Preparation of Wiring Database. . Logic development as per Process write-up.Academics:|Education |Institution |Year of |% Of |Remarks || | |Passing |Marks | ||BE |S.G.G.S I & T, Nanded. |June-2006|70% |Distinctio||(Instrumentation) | | | |n ||H.S.C (XII) |M.G.M College, Ahemdpur, Dist.|June-2002|89.46% |Distinctio|| |Latur. | | |n ||S.S.C. (X) |Gyan Mata Vidya Vihar School,|May-2000 |80.80% |Distinctio|| |Nanded | | |n |Personal Details: . Marital Status - Married. . Nationality - Indian. . Languages known: English, Hindi . Date of Birth: 06th August 1984. . PASSPORT NO: F9872913Present Address:Room no. 1305, Hansan Officetel, 121-44 Dangsan-dong,Yeongdeungpo-gu, Seoul, South Korea.Mobile: +82-10-3148-2135.Permanent Address:C/o Heerasingh Gour, Renuka Niwas, A-1, Madhuban Residency,Opp. Shama Gas Agency, Purna Road, Nanded - 4310605 (MS) India.Mobile: PHONE NUMBER AVAILABLE (India) |