| 20,000+ Fresh Resumes Monthly | |
|
|
| | Click here or scroll down to respond to this candidateCandidate's Name JR.Saudi Oger LTD.,Thuwal,Jeddah,Saudi ArabiaMobile No: PHONE NUMBER AVAILABLE/PHONE NUMBER AVAILABLEEmail Add: EMAIL AVAILABLE/fernandezjenerio@gmail.comSkype Account: fernandezStreet Address
Seeking a challenging opportunity that can share my ability and skills topromote company goals andobjectives-----------------------------------------------------------------------------------------------------EMPLOYMENT DETAILSSaudi Oger Limited [KAUST Project]Jeddah,Kingdom of Saudi ArabiaFire Alarm System Maintenance TechnicianSeptember 07,2012-Present Duties and Responsibilities . Conducting daily Preventive Maintenance (PPM) for fire alarm system inResidential and Facilities The testing was applicable in accordance with NFPA 72 National FireAlarm Code Coordinate from security and fire department prior to start the task toprevent miscommunication . Handling Fire Alarm brand:Edward System Technology products-Quick StartPanel,and EST3 Panelconventional and analog addressable system combination of FM200 firesuppression system . Responsibilities for installation,troubleshooting,programing andtesting of fire alarm system . Performed semi and annual inspections and preventive maintenanceservice of fire alarm system . Installed,modefies,maintained program and repair fire alarm panels suchas QS1,QS4 and EST3 . Installed pullstations,smoke,heat,duct detectors and relay modules sigaCR,CT1,CT2,CC1,etc.... . Connected fire alarm open-close relay modules (siga CR) to 24v supplyfrom contactors of three phase motors of AC/HVAC and elevators,purpose of automaticaly CUTOFFduring alarm activited . Examine system to locate problems such as loose connections or brokeninsulations . Adjusts sensitivity of units (smoke devices) based on room structuresand recommendations . Test device detectors and checked dirty percentage (80% dirty need tobe replaced) . Checked backup batteries (not lower than 24v DC,replace if needed) . Test and checked load voltage and discharge voltage (ON alarmstatus,not lower than 24V DC) . Test charging voltage (OFF alarm status,not lower than 26 volts DC) . Replaced PS6 Card,SLIC Card, changing device detectors and adddetectors,modules,SLIC Card . Resolved communication fault trouble,unconfigure device,loop wiring,mapfault,internal trouble,etc. . Resolved hornstrobe and siga CR (Control Relay) not function (responseprogram) . Checked panel program ensuring device massages are correct in itslocation . Configuration,Disable and Enable loop maping for changing device ormodule if needed . Maintain records,files and preparing reports and orders of materials touse . Complies with all applicable health and safety procedures policies andstablished work practicesCiti Hardware IncorporatedDumaguete City,Negros Or.,PhilippinesElectrical Maintenance and ServicesMay 2005-May 2012 Duties and Responsibilities . Read and interpret blue prints for the purpose of determining efficientinstallation . Maintained,repaired,installed troubleshooting lectrical wiringconnections . Spliced,joined,insulated wire,pull wires,put into tubing and fixed towall and other concealed areas . Performed building wiring and house wiring connections . Connected 3way and 4way switch,connected wires,cables to circuitbreakers,socket outlets and other components using electrical tools and power tools . Performed wiring for upgrade and expansions------------------------------------------------------------------------------------------------------ACADEMIC BACKGROUND4yr. College Degree Negros Oriental State University Year completed 2004Electricity MajorHigh School San Miguel Prv'l.Com.High SchoolYear completed 2000------------------------------------------------------------------------------------------------------CERTIFICATEWORK PERMIT RECEIVER Saudi Oger Ltd. ( KAUST Project )Exp.June 2015for Cold work,Hot work and Confined Space EntryCert.no. 180713130------------------------------------------------------------------------------------------------------SKILLS . Computer literate MS word,Office tools,Internet surfing . Fluent in Oral and Written English Communication Skills . Teamwork,Coordination,Time management,Reporting Skills,Dependability------------------------------------------------------------------------------------------------------REFERENCES Mr. Danilo G. Due Engr. Glend P.Sedentario Asst. Manager Bldg. Control and System Duty Manager EMCOR company (ARAMCO Project) EMCOR FacilitiesServices PHONE NUMBER AVAILABLE PHONE NUMBER AVAILABLE Email: EMAIL AVAILABLEEMAIL AVAILABLE |