Quantcast

Electrical Technician Resume Doha,
Resumes | Register

Candidate Information
Name Available: Register for Free
Title Electrical technician
Target Location QA-Doha
Email Available with paid plan
Phone Available with paid plan
20,000+ Fresh Resumes Monthly
    View Phone Numbers
    Receive Resume E-mail Alerts
    Post Jobs Free
    Link your Free Jobs Page
    ... and much more

Register on Jobvertise Free

Search 2 million Resumes
Keywords:
City or Zip:
Related Resumes

Technical Support Specialist / IT Support Specialist / Helpdesk Doha

Accountant Doha

Procurement Officer Doha

3+ years of experience as an Account Executive Hands on experien Doha

IT specialist Doha

Male Nurse Doha

Click here or scroll down to respond to this candidate
                                        RESU M E




                                                            Z ahid Ali

Objective: To pursue a career in a dynamic and well-reputed firm to apply my technical and
managerial skills in a challenging environment and contribute towards growth of the firm


                                       JOB SU M M ARY
Having a 11 years experience in electrical fields and have been working in fertilizer plant since 2006
to now, have been performing the preventive and corrective and periodic maintenance of the
electrical machines and equipment according with electrical safety rules and regulation

                            Academic and I ndustrial T raining
       Diploma of associate Engineering Electrical in 2004 from Lahore board of technical education
        and got the 76% marks

       Matriculation in science subjects attained the 74% marks from Bahawalpur board in 2001

       Apprenticeship two years duration from Fauji fertilizer Company Mirpur Mathelo in 2006

                                        P rofessional profile
        Qatar fertilizer company sate of Qatar
Working as an Electrical Technician since 2011 to till

Performing the numerous maintenance task and responsible the following subject

       Preventive corrective and periodic maintenance of electrical machines and switch gear

       Equipment fault history and maintenance record logging in CMMS JD Edward

       Plan the plant shut down activities and contract man power management

       Handle the plant emergency activities and trouble shoot the faults

1
       Ensure the all job has been done according to safety rules and regulation

       Participate in monthly safety walk and audit the electrical installation

        Fauji Fertilizer Company Mirpur Mathelo Pakistan
        Worked in Fauji Fertilizer Company from 2006to 2011 as an Electrical Technician

              Participated in cooling tower motor and switch gear replacement power and control
               cables laying glanding and termination

              Worked as shift Technician and responsible to handle electrical emergency on plant and
               breaker isolation and inspection of Generator slip rings and carbon brushes
               replacement

              Worked as auxiliary fire fighter to control the emergency on plant




                     WOR K I N G E XPER I E NC E A N D S K I L LS

          T RANSFOR M ER MA I N T E NANCE AND TEST I NG
       Maintenance of transformer rating 55MVA, 66KV (AREVA, SIEMENS)

       Power and control cables termination Sampling of oil, break down voltage test. Dissolving gas
        analysis test and routine inspection of transformer

G ENERATOR AND M O TOR MA I N T E NANCE
       Generator rating 46MVA(Brush made) routine inspection overhauling winding tests and
        extraction of rotor and inspection of slip rings and replacement of carbon brushes

       MV motors rating 3.2 MW(ABB.SCHORCH) maintenance bearing replacement rotor extraction
        inspection and winding test PI and DAR

       Termination box insulator, rotor bars and stator winding inspection

SUBSTA IO N SWI TC HGEAR AND BREAKER (ABB,MAGR I N I GALEL IO
A REAVA)

       Maintenance of GIS switch gear(ABB) sf6 circuit breaker testing gas filling and checking of
        closing and opening mechanism

       Oil circuit breaker air circuit breaker and vacuum circuit breaker maintenance inspection

2
U PS       PANEL          (GUTOR,           CEG)        AND        BATTER I ES           (HOPPECK)
M A I N T E NANCE

       Worked on UPS panel fault rectification and maintenance

       Batteries bank maintenance gravity test and impedance test

F I RE DE TECT IO N, SUPPERS ION SYSTE M AND SIREN SYSTE M
       Fire alarm panel fire detection devices smoke ,heat, beam and flame detector (AUTRONICA
        AND SIMPLEX)

       Fire extinguisher system Inergen, Novec and Clean agent panel maintenance and fault
        rectification

       Public warning unit siren panel Sircom and Horman maintenance and logic designing and fault
        rectification

M ISSELENOUS P LAN T JOBS

       Maintenance of over head crane 35ton rating hoisting and cross moving motors brake
        adjustment and pendent wiring

       Worked on motor operated valve ROTORK made torque, opening and closing adjustment

       Welding and lathe machines overhauling and fault rectification

       Worked on variable speed devices ABB fault rectification and setting

       Worked on plant cathode protection system

       Relay testing equipment secondary current injection set

       Low voltage cable jointing, glanding and termination

       Inspection and testing of electrical devices overload relay circuit breaker and magnetic
        contactor etc.

       Inspection of electrical motors and brake adjustment of the ship loader



          D IST I NCT I VE ROLE
       Alignment and testing of Substation fire safety equipment beam detector, flame detector and
        interfacing With plant fire alarm system

       Audit of electrical power DBs and installation fault identification and prevention



3
       Chemical store and ware house fire safety equipment aspiration detectors ,flame detectors
        and manual call points maintenance and trouble shooting

       Transformer and long range conveyor belts fire safety thermo sensitive cable connection
        inspection and trouble shooting

       Performed the role of evacuation team leader during building fire coordinate with fire fighter
        and assist about electrical installation isolation

       I N D USTR IAL T RA I N I NG

       Passed the EX equipment maintenance training (loughbourgh London)

       Passed the MOVs maintenance training ROTORK

       Plant safety and hazardous area and integrated HSEQ training

       Work permit and lock out and tag procedure training

       Attended the confined space entry and its hazard training



                         PE RSONAL D E TA I LS

NAME                         ZAH ID AL I
FATHER NAME                  MU HAM MAD HAN IF
MARTIAL                      MARRIED
STATUS
PASS PORT                    ZE1791322
CNIC                         3130462841323
CONTACTS                     PHONE NUMBER AVAILABLE,PHONE NUMBER AVAILABLE
EMAI L                       ZAH EMAIL AVAILABLE
POSTAL                       FAUJI CLOTH HOUSE SANJARPUR TEHSILE
A DDRESS                     SADIQ ABAD
                             DISTRICT RAH I M YAR K HAN PUNJAB
    COUNTRY                  VALID QATARI RESISDENCE PERMIT AND
    STAY                     DRIVING L ICENSE



4
5

Respond to this candidate
Your Email «
Your Message
Please type the code shown in the image:
Register for Free on Jobvertise