Search Jobvertise Jobs
Jobvertise

Infrastructure PM (Public safety/HVAC/Power) - Onsite
Location:
US-DC-Washington
Jobcode:
tokhrv
Email this job to a friend

Report this Job

Report this job





Incorrect company
Incorrect location
Job is expired
Job may be a scam
Other







Apply Online
or email this job to apply later

Title: Infrastructure PM (Public safety/HVAC/Power) - Onsite
Location: Washington, DC, United States
Length: Long term
Restriction: w2 or c2c or 1099

Description:

W2 or 1099 or c2c ***webcam interview Long term project usually the project goes for multiple years with this customer. *** Onsite ***

Short Description:

16+ years of experience. Supports OUC IT by monitoring, managing, and optimizing the 911 datacenters physical infrastructure. Provides expertise to redesign the 911 datacenter as required based on industry standards and best practices.

Job Description:

The OUC needs to hire a resource that will be accountable for evaluating the electrical, environmental, and data capacity of the call floor in connection with its expansion. This resource will perform an assessment that will encompass identifying risks linked to potential outages affecting critical data, environmental conditions, or electrical services. The assigned resource will consistently update existing risk mitigation strategies and alert protocols for critical services, supporting both the data center and the 911 call floor. Additionally, the resource will:

Responsibilities:

Monitor, notify and report power or HVAC related alerts, promptly reporting any issues that may impact the call floor operations team.
Coordinate and collaborate on maintenance or repair activities that could potentially affect call floor operations.
Scrutinize all change requests related to upgrades or maintenance that might influence call floor operations and provide guidance to operations managers.
Generate a weekly report detailing the performance of critical infrastructure.
Stay abreast of industry best practices in data center and 911 center operations, identifying any existing gaps.
Facilitate necessary failover testing on critical infrastructure and 911 applications.
Monitor and report on any cybersecurity risks affecting the call floor.
Monitor and report on patch management for all servers that support the call floor.
Organizes, directs, and manages contract operation support functions, involving multiple, complex, and inter related project tasks.
Manage data center projects, including coordinating with vendors and contractors, tracking progress, and meeting deadlines. Provide technical guidance and support to ensure successful project implementation.
Conducts regular inspections of equipment to ensure optimal performance and reliability.
Using existing OUC tools, Monitor and analyze power usage, temperature, and humidity levels in the data center to identify and resolve any issues or inefficiencies.
Management and coordination with vendors and contractors to ensure equipment is properly installed, maintained, repaired, and replaced as needed.
Develop and implement procedures and protocols for equipment maintenance, emergency response, and disaster recovery.
Document and maintain accurate records of all equipment, maintenance activities, and infrastructure changes.
Oversee all aspects of the data centers critical physical infrastructure.
Ensure that all work performed within the space is done to high quality and without impact to internal/external customers.
identify improvement areas in existing and next generation data center designs according to industry standards to address: master planning building architectural systems, constructability and sustainability.
Forecasting future requirements to support evolving information technology solutions to support redundant emergency operations.
Draft or review RFPs related to the data centers design and equipment upgrades
Provide relevant feedback for datacenter improvements as required.
Provide and enforce the standards by which electrical and mechanical systems including cable management, airflow, physical security in a critical infrastructure environment are to be operated and maintained.
Facilitate data center audit for facility infrastructure.
Provide technical expertise for root cause analysis and remediation recommendations as required.
Investigate incidents involving failures and or interruptions of the IT infrastructure oversee the resolution and preventative actions to mitigate future occurrences.

Minimum Education/Certification Requirements:

Education in information technology with a degree in Computers, Information technology or electrical engineering.
Data center and call center engineering and management
Understanding Data Center Infrastructure Tier Standard Topology
Excellent computer skills including basic understanding of WAN, LAN systems, servers, routers, and switches.
Knowledge of cybersecurity and patch management.
Understanding of the electrical systems involved in critical data center operations such as: feeders, transformers, generators, switchgear, UPS systems, Automatic Transfer Switch (ATS), units, Programmable Logic Controllers (PLC), Power Distribution Units (PDUs) and Static Switches
in depth knowledge of the electrical & mechanical infrastructure required to support data center environments.
Proficiency in the design and operation of data center critical facility infrastructure. This includes UPS, Cooling, airflow, cable management, and backup power systems. The ability to present complex engineering subject matter to a non technical audience. Effective interpersonal and communication skills (written and oral) to communicate with all levels of the organization.

Required Skills:

16+ yrs. in progressive consulting leadership role, providing full lifecycle services in enterprise environment 16 Years
16+ yrs. managing, coordinating, and establishing priorities for entire project lifecycle 16 Years
Bachelors degree in IT or related field or equivalent experience
15 years of experience managing complex projects 15 Years
15 years of experience in public safety radio, data networks and facilities (HVAC, power and physical security) 15 Years
5 years of experience with architectural design / remediation of new / existing industrial or commercial or other complex technical projects. 5 Years
2+ years of experience with architectural design of mission critical projects.2Years
3 years of experience designing and deploying data center infrastructure, including power distribution, cooling systems, and equipment layout 3 Years
3 years of experience in conducting regular inspections, maintenance, and troubleshooting of datacenter infrastructure to identify and resolve issues 3 Years
2 years of experience managing data center projects including coordinating with vendors and contractors, tracking progress, and meeting deadlines. 2 Years
5 years of experience managing scope, schedule, cost of network, optimization, etc. 5 Years

Highly Desired Skills:

Knowledge of industry standards and best practices: Familiarity with industry standards and best practices, such as TIA 942, Uptime Institute Tier Sta

Desired Skills:

3 years of experience in data center engineering 3 Years

msysinc

Apply Online
or email this job to apply later


 
Search millions of jobs

Jobseekers
Employers
Company

Jobs by Title | Resumes by Title | Top Job Searches
Privacy | Terms of Use


* Free services are subject to limitations